Related Experiment Video
Updated: Sep 18, 2025

Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
Published on: September 2, 2015
Digitalized Thermal Inspection Method of the Low-Frequency Stimulation Pads for Preventing Low-Temperature Burn in
HyungTae Kim1, Jong-Ik Song2, Ji-Won Seo2
1Korea Institute of Industrial Technology, Ansan 15588, Republic of Korea.
Abstract:
An accurate thermal measurement of low-frequency stimulation (LFS) pads for thermotherapy was investigated using background subtraction (BGS) methods. The safety of LFS thermal pads must be investigated to prevent low-temperature burns (LTBs), because they frequently contact the sensitive skin in neck, shoulder and abdominal regions. The thermal measurement was based on thermal imaging using the active region-of-interest (ROI) from a foreground. The shape of the LFS thermal pad consists of complicated curves, thus it is difficult to extract the foreground using conventional shapes of ROIs. We proposed the foreground extraction using background subtraction (BGS) and digital and morphological filters to time-variant thermal images. The foreground extraction was implemented using open sources and experimented for abdominal, cervical and patellar pads. The results showed that the foreground can be separated from background regardless of the size, position, orientation and shape of the pad. The thermal characteristics of the LFS thermal pads were evaluated from the complicated shapes of the foreground with high accuracy. This study demonstrated that standard deviation of pixel history (SDPH) is a simple method for the BGS, but the SDPH is useful to find the safety risk of LTBs and prevent them in advance. The results also showed that the proposed SDPH was simple but had remarkable accuracy compared with the conventional BGS methods. These BGS methods are expected to increase the reliability of products used on the human body. Further, the BGS methods can be used to inspect the temperatures of static products in industrial processes.
More Related Videos
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
09:16Multi-Modal Signals for Analyzing Pain Responses to Thermal and Electrical Stimuli
Published on: April 5, 2019
Related Concept Videos
Decreased Body Temperature
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Thermosensation