Related Experiment Video
Updated: Sep 18, 2025

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Improvement of Colonoscopic Image Quality Using a New LED Endoscopic System with Specialized Noise Reduction
Naohisa Yoshida1, Masahiro Okada2, Yoshikazu Hayashi2
1Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan.
Abstract:
Background/Objectives: A new LED endoscopy system featuring advanced noise-reduction technology, the EP-8000 with the EC-860ZP colonoscope (Fujifilm), was introduced in 2024. We evaluated the improvements in colonoscopic image quality of this system, comparing it with a previous system/scope (VP-7000/EC-760ZP). Methods: This is a multicenter, observational study. From January 2024 to February 2025, 150 patients undergoing colonoscopy at two institutions were enrolled. Images of the cecum and lesions were captured using white light imaging (WLI), blue light imaging (BLI), and linked color imaging (LCI) under similar conditions. Participants were divided into three groups: Group 1 (EP-8000+EC-860ZP; 50 cases), Group 2 (EP-8000+EC-760ZP; 50 cases), and Group 3 (VP-7000+EC-760ZP; 50 cases). Cecal and lesion images were evaluated for brightness, halation, and visibility using a four-point scale (1 = poor to 4 = excellent) by endoscopists and original values by image-analysis software. Results: In cecal images, the endoscopists' scores in Group 1 were significantly better than in Group 3 for brightness (WLI: 3.71 ± 0.55 vs. 3.51 ± 0.58, p < 0.001, BLI: 3.15 ± 0.85 vs. 2.23 ± 0.92, p < 0.001; LCI: 3.83 ± 0.42 vs. 3.54 ± 0.58, p < 0.001) and for halation (WLI: 3.60 ± 0.51 vs. 3.18 ± 0.59, p < 0.001, BLI: 2.99 ± 0.69 vs. 2.71 ± 0.78, p < 0.001; LCI: 3.33 ± 0.60 vs. 3.10 ± 0.58, p < 0.001). Software analysis confirmed that Group 1 had superior brightness values compared with Group 3 for WLI, BLI, and LCI, as well as lower halation values for WLI and LCI. Regarding lesion images, brightness, halation, and visibility for WLI, BLI, and LCI were superior in Group 1 than in Group 3. Conclusions: The new LED system provided improvements in brightness, halation, and lesion visibility.
More Related Videos
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...