Related Experiment Video
Updated: Sep 18, 2025

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
The Development of a Sensitive and Selective Method for the Quantitative Detection of Ricin via ICP-MS Combined with
Long Yan1, Kexuan Li1, Jina Wu1
1State Key Laboratory of Chemistry for NBC Hazards Protection, Beijing 102205, China.
None:
As a type II ribosome-inactivating protein (RIP-II) toxin, Ricin has garnered widespread recognition due to its inherent qualities as an easily prepared and highly stable substance, posing serious implications as a potential chemical and biological terrorist threat. For the detection of ricin, traditional immunoassay technologies, including methods like peptide cleavage combined with liquid chromatography mass spectrometry (LC-MS) or the more commonly used enzyme-linked immunosorbent assay (ELISA), have offered reliable results. However, these techniques are unfortunately limited by the requirement of a complex sample pretreatment process, which can be time-consuming and labor-intensive. In an effort to overcome these limitations, a highly sensitive and selective method was introduced via metal element labeling combined with inductively coupled plasma mass spectrometry (ICP-MS) in this research. The method centered on designing and synthesizing a europium-labeled compound (DOTA-NHS-Eu) that specifically targets the amino groups (-NH2) on ricin. The compound, coupled with the application of specific magnetic beads, achieved the specific enrichment and subsequent quantitative detection of ricin by ICP-MS, which is based on the amount of europium element present. The established method demonstrated high specificity for ricin recognition, with a signal response to bovine serum protein that was found to be less than 10% of that for ricin. Furthermore, the calibration curve created for the method (y = 81.543x + 674.02 (R2 > 0.99)) for quantifying ricin in a concentration range of 1.0-100 μg/mL demonstrated good linearity. The method was further evidenced by the limit of detection and quantitation results of 0.1 and 1.89 μg/mL, respectively. Collectively, these findings suggested that the research has offered a highly sensitive and selective method for ricin detection, which was not only easy to operate but also provided efficient results. The scheme showed great potential for the verification of chemical weapons and the destruction of toxic chemicals, therefore representing a significant advancement in the field of biomolecular detection and analysis.

