Related Experiment Video
Updated: Sep 18, 2025

Color Spot Test As a Presumptive Tool for the Rapid Detection of Synthetic Cathinones
Published on: February 5, 2018
Rapid and sensitive determination of etomidate based on colorimetric assays with a chromium(III) complex
Leo K B Tam1, Weijun Ma2, Boyang Li2
1Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, PR China. leo-kb.tam@polyu.edu.hk.
Abstract:
Vaping etomidate is currently a red-hot social issue where the drug abuse problem has led to health concerns and even reported deaths for adolescents. Therefore, a fast, sensitive, and cost-effective detection tool for etomidate is urgently needed to support law enforcement. A chromium(III) complex-based sensor, EtoChrom, is presented in this work as an example of a detection method for etomidate based on a colorimetric assay. This low-priced but novel sensor exhibits an eye-catching colour change from purple to yellow and a bathochromic shift in the absorption band upon etomidate binding. Thus, the result can be seen directly by the naked eye. EtoChrom demonstrated a high precision of up to 2 mg mL-1 etomidate with a low detection limit of 0.030 mg mL-1, with the interference from the vape juice and saliva matrices negligible throughout the test. In real etomidate-containing vape juice analysis, EtoChrom can provide accurate results within 1 min, revealing its high potential to serve as an easy-to-handle and cost-effective etomidate detector for rapid on-site screening.
More Related Videos
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Complexometric Titration: Overview
EDTA: Indirect and Alkalimetric Titration
Redox Titration: Iodimetry and Iodometry
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...

