A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine
Published on: December 6, 2024
Accuracy of Estimated Blood Loss on Common Operating Room Items Among Medical Professionals
Bryanna D Vesely1, Jennifer Kipp1, Luke Leffler1
1*Department of Orthopaedic Surgery, Wake Forest Baptist Medical Center, Winston-Salem, NC.
Background:
Hemostasis during surgery is a primary contributor to the patient's blood management. Accurate blood loss estimation from surgery can help teams with postoperative management. The goal of this study was to analyze the accuracy of medical workers' estimations of blood loss on different operating room items.
Methods:
A survey was sent out to medical students, residents, and attendings in a single academic institution. The survey asked participants to estimate the amount of simulated blood from pictures of a laparotomy sponge (lap), Ray-Tec sponge, towel, and drape.
Results:
There were 124 participants in the survey. All average estimations were greater than the actual amount of simulated blood on the operating room item. There was a statistically significant difference in estimations between students, residents, and attendings in all categories except Ray-Tec #1. The residents were closest in estimation in all categories; however, this was not statistically significant compared with attendings. When comparing the estimations of surgical and nonsurgical specialties, surgical specialties were the most accurate except for the estimation of laps.
Conclusions:
All in all, our study found a substantial overestimation of blood on operating room items by residents, students, and attending physicians. Our study suggests that estimation of surgical blood loss by analysis of soaked Ray-Tec sponges, laps, drapes, and towels may be inaccurate.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...