Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Digital twins suggest a mechanistic basis for differing responses to increased flow rates during high-flow nasal
Hossein Shamohammadi1, Sina Saffaran1, Roberto Tonelli2
1School of Engineering, University of Warwick, Coventry, CV4 7AL, UK.
Background:
Inconsistent responses to increased flow rates have been observed in patients with acute hypoxemic respiratory failure (AHRF) treated with high-flow nasal cannula (HFNC) therapy, with a significant minority in two recent studies exhibiting increased respiratory effort at higher flow rates. Digital twins of patients receiving HFNC could help understand the physiological basis for differing responses.
Methods:
Patient data were collated from previous studies in AHRF patients who were continuously monitored with electrical impedance tomography and oesophageal manometry and received HFNC at flow rates of 30, 40 or 45 L/min. Patients, based on their responses to an increase in flow rate to 60 L/min, were categorised into two groups: five responders with reduced oesophageal pressure swings ΔPes (- 3.1 cmH2O on average), and five non-responders with increased ΔPes (+ 2.0 cmH2O on average). Two cohorts of digital twins were created based on these data using a multi-compartmental mechanistic cardiopulmonary simulator. Digital twins' responses to increased HFNC flow rates (60 L/min) were simulated with constant respiratory effort to assess changes in gas exchange and lung mechanics, and with varying respiratory effort to quantify their combined effects on lung mechanics and P-SILI indicators.
Results:
The digital twins accurately replicated patient-specific responses at all flow rates. Responder digital twins showed a mean 20 mL/cmH2O increase in lung compliance at higher flow rates, versus a 6 mL/cmH2O decrease in compliance with non-responders. In digital twins of responders versus non-responders, increased flow rates produced a mean change in lung stress of - 1.5 versus + 1.2 cmH2O, in dynamic lung strain of - 8.8 versus + 16.4%, in driving pressure of - 1.3 versus + 1.1 cmH2O, and in mechanical power of - 0.8 versus + 1.2 J/min. Higher flow rate dependent positive end-expiratory pressure in digital twins of non-responders did not cause recruitment, and reduced tidal volumes due to higher functional residual capacities-to compensate for the resulting worsened gas-exchange, non-responders increased their respiratory effort, in turn increasing patient self-inflicted lung injury (P-SILI) indicators. In digital twins of responders, reductions in tidal volumes due to higher FRCs resulting from increased PEEP were outweighed by alveolar recruitment. This increased compliance and improved gas exchange, permitting reduced respiratory effort and decreases in P-SILI indicators.
Conclusions:
Failure to reduce spontaneous respiratory efforts in response to increased HFNC flow rates could be due to a deterioration in lung mechanics, with an attendant risk of P-SILI.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation I: Indication and Settings