Microwire vs. Micro-Ribbon Magnetoelastic Sensors for Vibration-Based Structural Health Monitoring of Rectangular
Christos I Tapeinos1, Dimitris Kouzoudis1, Kostantis Varvatsoulis1
1Department of Chemical Engineering, University of Patras, 26504 Patras, Greece.
Abstract:
Two different magnetoelastic Metglas materials with distinct shapes were compared as sensing elements for the structural health monitoring of concrete beams. One had a ribbon shape, while the other had a microwire shape. The sensing elements were attached to different concrete beams, and a crack was introduced into each beam. The beams were subjected to flexural vibrations, and their deformations were recorded wirelessly by coils, detecting the magnetic signals emitted due to the magnetoelastic nature of the sensors. Fast Fourier Analysis of the received signal revealed the bending mode frequencies of the beams, which serve as a "signature" of their structural health. In these spectra, the ribbon-shaped sensor exhibited a 1.4-times stronger signal than the microwire sensor. However, the extracted mode frequencies were nearly identical, with differences of less than 1% both before and after damage. This indicates that both sensors can be used equivalently to monitor structural damage in concrete beams. The damage-related relative frequency shifts ranged from -0.01 to -0.03, with similar results for both sensors. Thermal annealing was also studied and appeared to significantly enhance the signal by 10-30%, likely due to the relaxation of internal stresses induced during the rapid solidification synthesis of these materials. This enhancement was more pronounced in the ribbon-shaped sensor. This study is the first to utilize a magnetoelastic microwire sensor for damage detection in concrete beams.
Related Concept Videos
Distribution of Stresses in a Narrow Rectangular Beam
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Microcracking in Concrete
Beams with Symmetric Loadings
The M/EI...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...