Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Robust Estimation of Unsteady Beat-to-Beat Systolic Blood Pressure Trends Using Photoplethysmography Contextual
Xinyi Huang1, Xianbin Zhang1, Richard Millham2
1School of Biomedical Engineering, Sun Yat-sen University, Shenzhen 518107, China.
None:
Hypertension and blood pressure variability (BPV) are major risk factors for cardiovascular disease (CVD). Single-channel photoplethysmography (PPG) has emerged as a promising daily blood pressure (BP) monitoring tool. However, estimating BP trends presents challenges due to complex temporal dependencies and continuous fluctuations. Traditional methods often address BP prediction as isolated tasks and focus solely on temporal dependencies within a limited time window, which may fall short of capturing the intricate BP fluctuation patterns implied in varying time spans, particularly amidst constant BP variations. To address this, we propose a novel deep learning model featuring a two-stage architecture and a new input structure called contextual cycles. This model estimates beat-to-beat systolic blood pressure (SBP) trends as a sequence prediction task, transforming the output from a single SBP value into a sequence. In the first stage, parallel ResU Blocks are utilized to extract fine-grained features from each cycle. The generated feature vectors are then processed by Transformer layers with relative position encoding (RPE) to capture inter-cycle interactions and temporal dependencies in the second stage. Our proposed model demonstrates robust performance in beat-to-beat SBP trend estimation, achieving a mean absolute error (MAE) of 3.186 mmHg, a Pearson correlation coefficient applied to sequences (Rseq) of 0.743, and a variability error (VE) of 1.199 mmHg. It excels in steady and abrupt substantial fluctuation states, outperforming baseline models. The results reveal that our method meets the requirements of the AAMI standard and achieves grade A according to the BHS standard. Overall, our proposed method shows significant potential for reliable daily health monitoring.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement