Characterizing the Cracking Behavior of Large-Scale Multi-Layered Reinforced Concrete Beams by Acoustic Emission
Yara A Zaki1, Ahmed A Abouhussien2, Assem A A Hassan1
1Department of Civil Engineering, Faculty of Engineering and Applied Science, Memorial University of Newfoundland, St. John's, NL A1B 3X5, Canada.
None:
In this study, acoustic emission (AE) analysis was carried out to evaluate and quantify the cracking behavior of large-scale multi-layered reinforced concrete beams under flexural tests. Four normal concrete beams were repaired by adding a layer of crumb rubberized engineered cementitious composites (CRECCs) or powder rubberized engineered cementitious composites (PRECCs), in either the tension or compression zone of the beam. Additional three unrepaired control beams, fully cast with either normal concrete, CRECCs, or PRECCs, were tested for comparison. Flexural tests were performed on all the tested beams in conjunction with AE monitoring until failure. AE raw data obtained from the flexural testing was filtered and then analyzed to detect and assess the cracking behavior of all the tested beams. A variety of AE parameters, including number of hits and cumulative signal strength, were utilized to study the crack propagation throughout the testing. Furthermore, b-value and intensity analyses were implemented and yielded additional parameters called b-value, historic index [H (t)], and severity (Sr). The analysis of the changes in the AE parameters allowed the identification of the first crack in all tested beams. Moreover, varying the rubber particle size (crumb rubber or powder rubber), repair layer location, or AE sensor location showed a significant impact on the number of hits and signal amplitude. Finally, by using the results of the study, it was possible to develop a damage quantification chart that can identify different damage stages (first crack and ultimate load) related to the intensity analysis parameters (H (t) and Sr).
Related Concept Videos
Microcracking in Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Types of Non-structural Cracks in Concrete
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
Effects of Creep
Non-destructive Tests for Concrete Strength