Related Experiment Video
Updated: Sep 17, 2025

Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students
Published on: June 16, 2018
Assessment of pressure discomfort for over-ear wearables and the relationships with objective metrics
Yuan Cao1,2, Ruyang Yu3, Renke He2
1College of Furniture and Art Design, Central South University of Forestry and Technology, Changsha, China.
Abstract:
The objective of this study is to develop an enhanced methodology for analysing individuals' perceptions of discomfort due to the pressure exerted by over-ear headphones. Using principal component analysis and K-means clustering, we categorise 602 samples into six clusters and create representative Chinese head-and-ear models. A pressure tester was then developed to quantify the pressure exerted on head and ear regions by the headphone cushions. Thirty participants representing the proportional distribution of each cluster, were selected to evaluate subjective sensations through a long-term wearing test. The findings indicate a strong correlation between the pressure measurements obtained from the tester and the subjective assessments. Statistically significant differences were noted across various head models and clusters for both pressure-related parameters and subjective evaluations (p < 0.001). Additionally, women had higher pressure discomfort values than men in the ear-related regions. Finally, a regression model was developed to estimate overall pressure discomfort based on pressure-related parameters.
More Related Videos
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Factors Affecting Perception
An illustrative example of a perceptual set is the scenario where an airline pilot told...