Determinants of photoplethysmography signal quality at the wrist
Peter H Charlton1,2, Vaidotas Marozas3,4, Elisa Mejía-Mejía5
1Department of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom.
Abstract:
Wrist photoplethysmogram (PPG) signals are widely used for physiological monitoring in consumer devices. However, the PPG is highly susceptible to noise, which can reduce the accuracy of monitored parameters. The aim of this study was to identify factors which influence PPG signal quality. Data from the Aurora-BP dataset were used, consisting of reflectance wrist PPG signals measured from 1,142 subjects of varying ages and health statuses. Measurements were acquired in supine, sitting, and standing postures, and with the sensor held at different heights. Three signal quality metrics were calculated: the signal-to-noise ratio (SNR), the perfusion index (PI), and the template-matching correlation coefficient (TMCC). When comparing between postures with the sensor held at a natural height, quality was greatest in the supine position (SNR: 18.6 dB), followed by sitting with the arm resting in the lap (13.7 dB), and lowest whilst standing with the arm hanging alongside (9.0 dB) (p < 0.001). Signal quality increased as the arm was raised to heart height: whilst sitting, quality was lowest with the arm alongside the body (10.5 dB), and increased when the sensor was held in the lap (13.7 dB) and at heart height (15.5 dB) (p < 0.001). Similar trends were observed for the TMCC and PI. Findings were mixed for the influence of participant characteristics on signal quality. The SNR and TMCC, but not the PI, increased with age. The SNR either decreased or remained constant at darker skin tones when controlling for PPG DC amplitude, compared to constant or increased when allowing DC amplitude to vary. In conclusion, this study identified the impacts of posture and sensor height on signal quality, with highest qualities observed in the supine posture and with the sensor at heart height. It also highlights the importance of adjusting LED light intensity to maintain signal quality across skin tones.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pre-Procedural Guidelines for Assessing Blood Pressure
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.