Related Experiment Video
Updated: May 11, 2026

Development of an in vitro model system for studying the interaction of Equus caballus IgE with its high-affinity receptor FcεRI
Published on: November 1, 2014
Investigation of peptide cross reactivity in equine plasma using two adrenocorticotropic hormone immunoassays
1The Liphook Equine Hospital, Liphook, GU30 7JG, United Kingdom.
Abstract:
This study aimed to further define and quantify possible cross-reactive peptides when measuring plasma adrenocorticotropic hormone (ACTH) concentration in equids. Equine plasma samples were spiked with known concentrations of exogenous manufactured peptides comprising human ACTH1-39, ACTH18-39 (corticotropin-like intermediate lobe peptide, CLIP) and ACTH7-38 (corticotropin inhibiting peptide, CIP). All samples were assayed in duplicate using Siemens Immulite 2000xpi chemiluminescent assay (CLA) and Tosoh AIA-900 immunoflurorescent assay (IFA). As expected, ACTH1-39 was measured by both assays although higher values were reported using IFA (mean 132 % of actual concentrations) than CLA (mean 104 % of actual concentrations). ACTH18-39 was detected by the CLA but not the IFA (mean 29 % actual concentration) whereas ACTH7-38 was detected by the IFA, but not the CLA (mean 65 % actual concentration). The study further clarifies that these ACTH immunoassays are likely to report higher measured ACTH1-39 concentrations than are actually present in the sample although additional work is needed to elucidate the diagnostic and pathophysiologic implications of these findings.