Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
Corneal biomechanical property changes following corneal collagen cross-linking in keratoconus: a systematic review
Luksanaporn Krungkraipetch1, Angkhana Assawaboonyadech2, Dutdao Supajitgulchai2
1Department of Ophthalmology, Faculty of Medicine, Burapha University, Chonburi, Thailand. luksanaporn@go.buu.ac.th.
Purpose:
To evaluate the changes in corneal biomechanical properties following corneal collagen cross-linking (CXL) in keratoconus patients and determine factors influencing measurement sensitivity through systematic review and meta-regression analysis.
Methods:
A comprehensive literature search was conducted across PubMed, Scopus, Cochrane Library, and Google Scholar, identifying 8139 records. After duplicate removal and screening, 12 eligible studies (2009-2024) involving various CXL protocols and measurement tools (Corvis ST, Ocular Response Analyzer [ORA], and Ambrsio Relational Thickness [ART]) were included. Risk of bias was assessed using ROBINS-I and the NIH Quality Assessment Tool. Effect sizes were synthesized using random-effects meta-analysis, and heterogeneity was quantified using I2 statistics. Meta-regression was performed to evaluate associations between corneal stiffness and visual acuity outcomes. Publication bias was assessed through funnel plots, Egger's test, and trim-and-fill analysis.
Results:
CXL significantly improved corneal biomechanical properties, particularly when assessed with Corvis ST, which detected changes in 75% of studies, compared to 25% using ORA. Dynamic parameters such as V1, V2, and L2 were more sensitive than standard metrics. Meta-regression revealed a significant correlation between corneal stiffness and visual acuity for Corvis ST (p = 0.02 and p = 0.04, respectively), but not for ORA. The pooled effect size for biomechanical change was 0.74 (95% CI 0.59-0.89), reduced to 0.62 after Trim-and-Fill adjustment, suggesting 16.2% potential publication bias. Egger's test confirmed small-study effects (p = 0.024). Heterogeneity was high (I2 = 98.3%), attributed to variability in protocols and study designs.
Conclusions:
CXL leads to sustained improvements in corneal biomechanical properties in keratoconus patients, with stronger and more consistent detection using dynamic and device-specific metrics, particularly with Corvis ST. While findings support the long-term efficacy of CXL, variability in measurement protocols underscores the need for standardization. Meta-regression confirms the clinical relevance of biomechanical improvements, especially their correlation with visual function.
More Related Videos
12:25Second Harmonic Generation Signals in Rabbit Sclera As a Tool for Evaluation of Therapeutic Tissue Cross-linking TXL for Myopia
Published on: January 6, 2018
07:51Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
Related Concept Videos
Equivalent Couples
Two couples are considered to be equivalent if they produce the same rotational effect on a rigid body. In other words, the two couples have the same magnitude and act in the same direction, causing the same angular displacement or acceleration in the body.
For instance, consider two couples lying in the plane of the page, with one having a pair of equal...
Journal Bearings
To better understand the concept of journal bearings, consider a rope winch with dry or...
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Angle of Twist: Problem Solving
Residual Stresses in Circular Shafts
Transformation of Plane Stress