Related Experiment Video
Updated: Sep 17, 2025

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Cardiac Substructure Dose Reduction and Toxicity Risk Assessment: IMPT Versus IMRT for Breast Cancer
Lu Cao1,2, Han Zhao1,2, Shujun Zhang1,2
1Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
Purpose:
Intensity-modulated proton therapy (IMPT) significantly reduces mean heart dose (MHD), but data on cardiac substructure dose and toxicity compared to intensity-modulated radiation therapy (IMRT) are limited. This study evaluated dose reduction in cardiac substructures between IMPT and IMRT and assessed cardiac toxicity risks using 2 normal tissue complication probability models.
Materials And Methods:
A retrospective analysis was conducted on 30 breast cancer patients from a randomized trial with the highest MHD receiving IMRT. IMPT plans were created for a prescribed dose of 4005 cGy(RBE) in 15 fractions. Normal tissue complication probability models were used to compare individual acute coronary events (ACEs) risk between IMPT and IMRT.
Results:
Intensity-modulated proton therapy reduced cardiac substructure doses by 63.34% to 100%, with greater absolute reductions in left-sided and relative reductions in right-sided patients. For left-sided internal mammary node irradiation (IMNI), IMPT achieved an 82.25% reduction for left anterior descending coronary artery (P = .009), 79.45% for RV (P < .001), and over 90% for other substructures. Right-sided patients had near-zero mean doses in most substructures. The Darby model indicates IMPT reduces individual ACE risk by 1.58% to 5.16% for left-sided IMNI (P = .001) and 0.59% to 1.05% for right-sided IMNI (P = .063). The Bogaard model shows a 0.19% to 2.75% reduction in individual 9-year ACE risk-based MHD for left-sided IMNI (P = .0015). Risk reduction variations are influenced by dose reduction and other risk factors.
Conclusion:
Intensity-modulated proton therapy provides excellent cardiac protection, particularly for left-sided IMNI and high-risk patients.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...