Related Experiment Video
Updated: Sep 17, 2025

Murine Model of Central Venous Stenosis using Aortocaval Fistula with an Outflow Stenosis
Published on: July 11, 2019
Suprahepatic inferior vena cava stent placement for anastomotic stenosis
Zaid Nawaz1, Nicholas Gilbert2, Brendan Gontarz2
1Department of Surgery, Howard University Hospital, Washington, DC.
Abstract:
A 61-year-old female with previous liver transplantation was volume overloaded, requiring intubation and veno-venous extracorporeal membrane oxygenation. Workup was significant for mitral valve stenosis, for which she underwent repair. This was complicated by injury to the inferior vena cava with avulsion from the liver, which was reconstructed with bovine pericardium. Postoperatively, hemodynamic monitoring suggested poor venous return. She was taken for a venogram, demonstrating stenosis of the suprahepatic inferior vena cava, which was treated with placement of a bare metal self-expanding stent. This case report demonstrates an endovascular salvage technique for suprahepatic inferior vena cava stenosis after reconstruction during cardiac surgery.