Related Experiment Video
Updated: Sep 17, 2025

Three-Dimensional Reconstruction of Orbital Fractures
Published on: May 16, 2025
Intra-orbital Foreign Body
Shuaib Abdulsalam1, Eiman Bashir1, Nasir Abdulrashid1
1Department of Ophthalmology, Aminu Kano Teaching Hospital, Bayero University Kano, Kano, Nigeria.
Background:
This case report describes a young man with an intra-orbital foreign body (FB) in both eyes.
Case Report:
Intra-orbital FBs are rare, with few cases reported in the literature. This is because the orbit protects the globe from external forces, and the orbit is a closed cavity with one opening. This report details the case of a 28-year-old man who presented to the emergency unit with an 11-hour history of an intra-orbital FB. The patient was lying on a bench when a stationary motorcycle fell on him. He noticed that he was unable to open both eyes and was rushed to a peripheral hospital, then subsequently referred to this tertiary center. On examination, he was ill-looking and anxious but not febrile or pale. Systemic examination did not reveal any abnormality. Unaided visual acuity in the right eye (OD) was nil perception of light, while left eye visual acuity (OS) was counting fingers. The right eyelid was ptotic due to edema. He underwent basic laboratory investigations that were all normal. A plain X-ray revealed a radio-opaque FB penetrating the left orbit, fracturing the medial walls into the right orbit, with the round end positioned behind the right globe. The FB was identified as a broken part of a brake/clutch lever from the motorcycle. A computerized tomography scan showed a metallic object in both orbits, accompanied by pneumocephalus, and suggested transection of the right optic nerve. The patient was prepared for FB removal and repair of the lid penetration under general anesthesia, following review by the ENT surgeon and neurosurgeon. The brake lever was successfully removed, and the patient was administered antibiotics. Post-operatively, visual acuity in the right eye remained at nil perception of light, while that in the left eye improved to 6/9 upon discharge.
Conclusion:
There is no established protocol for managing intra-orbital FBs, as removal depends on factors such as the size, composition, and potential compression damage to structures around the globe, which could further compromise vision or function. Small inert objects may be left in place if removal would cause damage. However, in this case, removal was deemed necessary for several reasons.
Related Concept Videos
Accessory Structures of the Eye
Muscles of the Eye
Extraocular Muscles
The six extraocular muscles surround the eyeball and control its movements. They are responsible for a wide range of eye motions, including looking up, down, left, right, and...
Glaucoma: Overview
Anatomy of the Eyeball

