Related Experiment Video
Updated: Jun 19, 2026

Complete and Partial Aortic Occlusion for the Treatment of Hemorrhagic Shock in Swine
Published on: August 24, 2018
Morphometric analysis for resuscitative endovascular balloon occlusion of the aorta in women
Rachel M Russo1, Brian A Derstine, Jarom Ruby
1From the Department of Surgery (R.M.R.), University of California, Davis, Sacramento, California; University of Michigan, Data Scientist, Morphomics Analysis Group (B.A.D.), Ann Arbor, Michigan; Medical Corps (J.R.), United States Air Force, Surgical Operations Squadron, Obstetrics and Gynecology Flight; and Department of Surgery (S.H., J.L.E., S.C.W.), University of Michigan, Ann Arbor, Michigan.
Background:
The Joint Trauma System (JTS)'s resuscitative endovascular balloon occlusion of the aorta (REBOA) positioning guidance is derived from a predominantly male patient population. We aimed to validate these measurements in women.
Methods:
Aortic computed tomography scans of 404 women from a trauma patient data set were analyzed. The aorta was divided into anatomic zones based on REBOA literature, with zone 3 subdivided at the inferior mesenteric artery for pelvic surgery. Balloon placement analysis identified the frequency of out-of-zone placement errors for recommended insertion depths (46 cm for zone 1, 28 cm for zone 3) and determined optimal insertion depths to minimize these errors in women.
Results:
A 46-cm insertion depth reliably positioned the balloon in zone 1 99.3% of the time, while a 28-cm depth placed the balloon entirely in zone 3 65% of the time (64.3% left, 66.6% right). There were notable malpositioning rates, with balloons extending above the lowest renal artery (20.4%) or below the aortic bifurcation (13.6%). Balloon malposition was most frequent at extreme heights and weights. Adjusting balloon insertion depth to 48 cm improved zone 1 positioning (100%), while adjusting zone 3 positioning to account for differences in weight significantly reduced malpositioning errors. Zone 3b was commonly shorter than the 4-cm balloon, resulting in high rates of the balloon extending above or below the target zone.
Conclusion:
Fixed-length REBOA balloon placement can be performed in women with a low rate of malpositioning in zones 1 and 3. Adjusting for weight can further reduce the frequency of malpositioning when targeting zone 3. Restricting the target zone to below the inferior mesenteric artery may benefit from adjusting for weight or using image guidance.
Level Of Evidence:
Diagnostic Test or Criteria; Level III.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies

