Related Experiment Video
Updated: Sep 17, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Analysis and compensation method for nonlinear temperature error of fiber optic current transformer considering the
Zhang Zhu1, Zhang Xiaohang1, Zhou Shihao2
1School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, People's Republic of China.
Abstract:
As the main equipment for current monitoring in ultra-high voltage transmission systems, the measurement accuracy of the fiber optic current transformer (FOCT) directly affects the process of power grid digitization and intelligence. However, FOCT is significantly affected by temperature perturbations in actual operation, especially under the influence of a non-uniform temperature field triggered by multi-source factors such as conductor heating and environmental temperature, which causes the optical fiber linear birefringence to exhibit non-uniform distribution characteristics and consequently leads to excessive measurement deviation. Therefore, this paper reveals the correlation mechanism between the temperature gradient distribution driven by the conductor current-carrying capacity and the nonlinear error by establishing a mathematical model of the non-uniform temperature characteristics of FOCT. On this basis, an improved PSO-BP nonlinear temperature error compensation method (CTMC-PSO-BP), considering the Current-Thermal Multiphysics Coupling (CTMC), is proposed, which innovatively takes the conductor current-carrying capacity as an input parameter of the error compensation model. The results show that adding the conductor current-carrying capacity as an input parameter to the network can effectively improve the compensation effect of the model. The CTMC-PSO-BP neural network algorithm proposed in this paper demonstrates outstanding performance in the nonlinear temperature error compensation of FOCT, capable of reducing the measurement error of FOCT within the temperature range of 5-65 °C from ±0.4505% to within ±0.0026%, thereby substantially improving the performance of FOCT under the influence of complex temperature fields.
More Related Videos
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Related Concept Videos
Temperature Dependent Deformation
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Distance Corrections
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Controlled-Current Coulometry: Overview