Background:
A current limitation to the use of lung PET/CT is the absence of a tool that reliably and reproducibly quantifies the intensity of tracer uptake. We aim to develop a quantitative approach for lung perfusion PET/CT imaging. Sixty patients who underwent [68Ga]Ga-MAA PET/CT scans before (M0) and 3 months (M3) after completion of radiotherapy were analyzed. The anatomical lung volume (ALV) was delineated on the CT scan. CT and PET images were co-registered, and the ALV was transferred onto the PET images. The measured activity concentration (kBq/L) in each voxel was converted in three metrics: SUV based on normalizing the measured activity to the patient's weight (kg) and the injected dose (kBq); SUVp by normalizing to the ALV (L) and the injected dose (kBq); pulmonary uptake value (PUV) by normalizing to the ALV (L) and the total activity measured in the ALV (kBq). The mean SUV, SUVp and PUV values within the ALV were measured.
Results:
The mean (SD) SUV in the ALV was 9.90 (5.24) with an inconsistently wide range of values from 0.11 to 22.52. The correlation coefficient between the patient's weight and the ALV was 0.14. The mean (SD) SUVp in the ALV was 0.54 (0.09). The mean (SD) percentage of [68Ga]Ga-MAA lung retention was 58.2% (7.7%), with significant variability both between patients and within repeated scans of the same patient. The mean PUV in the ALV used for normalization was equal to 1. Quantitative methods were tested in challenging scenarios for quantification, including patients exhibiting decorrelation between ALV and patient's weight and patients with different percentage of [68Ga]Ga-MAA lung retention between M0 and M3. In contrast to the SUV and SUVp metrics, the PUV method showed coherent results compared to visual analysis.
Conclusion:
The patient's weight and the injected activity are not suitable parameters for normalization in lung perfusion quantification. We proposed a quantitative metric for lung perfusion PET/CT imaging, based on normalizing the measured activity to the ALV computed from a co-registered CT scan and to the total activity measured in the ALV.
Trial Registration:
NCT04942275. Registered 19 June 2021.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...