Related Experiment Video
Updated: Sep 17, 2025

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
Published on: August 30, 2016
Validation of markerless (Theia3D™) against marker-based (Vicon™) motion capture data of postural control movements
Peter Federolf1, Mareike Kühne1, Katharina Schiel1
1Department of Sport Science, University of Innsbruck, Innsbruck, Austria.
Abstract:
Markerless motion capture systems, such as Theia3D, offer a promising alternative to traditional marker-based systems (e.g., Vicon) not only for dynamic motion analysis, but also potentially for postural control research. The purpose of this study is to simultaneously derive and then compare principal movements (PMs) from Theia3D and Vicon data collected from 13 volunteers during eyes-open and eyes-closed bipedal quiet stance using principal component analysis (PCA). Agreement between systems was assessed by computing correlation coefficients for corresponding PM time series and evaluating their sensitivity to visual condition changes. Theia3D and Vicon produced highly similar PM structures, with the first two PMs-representing anterior-posterior ankle-strategy and medio-lateral sway-exhibiting near-perfect correlation (r = 99.8 % and r = 99.0 %) and explaining a comparable portion of the entire postural variance (PM1: 74 % vs. 76 %; PM2: 9.4 % vs. 9.9 % for Vicon and Theia3D results, respectively). The first seven PMs, which collectively accounted for 97 % of postural variance, showed strong agreement (r = 0.814 to 0.928) despite fundamental differences in marker placement and tracking methodology. Correlation declined in higher-order PMs, suggesting they capture distinct aspects of postural movements or system-specific noise. Both systems demonstrated comparable sensitivity to postural control modulations induced by visual deprivation. Notably, Theia3D exhibited higher noise levels, particularly in higher-order PMs, indicating that pre-processing with filtering should be considered before PCA. Overall, these findings confirm that Theia3D provides highly comparable results to Vicon for postural PMs, reinforcing its potential as a valid and efficient alternative for postural control research using PCA-based approaches.
More Related Videos
09:37Substantiating Appropriate Motion Capture Techniques for the Assessment of Nordic Walking Gait and Posture in Older Adults
Published on: May 12, 2016
11:06A Human-machine-interface Integrating Low-cost Sensors with a Neuromuscular Electrical Stimulation System for Post-stroke Balance Rehabilitation
Published on: April 12, 2016
Related Concept Videos
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Relative Motion Analysis - Acceleration
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...