Related Experiment Video
Updated: Sep 17, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Experimental study on mechanical properties of composite materials of concrete and foamed cement under uniaxial
Yue Cao1, Zheng Kong2, Yadong Zheng3
1School of Mining Engineering, China University of Mining and Technology, Xuzhou, 221116, China.
Abstract:
To investigate the mechanical properties of concrete-foamed cement composite specimens (C-FCCS), uniaxial compression tests were conducted on composite specimens with varying proportions and strengths of foamed cement. The analysis focused on the peak compressive strength, peak strain, macroscopic failure morphology, and acoustic emission (AE) characteristics of C-FCCS. The experimental results indicate that the peak compressive strength of C-FCCS exhibits a negative correlation with the proportion of foamed cement and a positive correlation with the proportion of concrete. At foamed cement proportions of 10% and 20%, the peak compressive strength of C-FCCS is predominantly governed by concrete, with AE energy concentrated primarily during the initial loading phase and near the peak stress. In contrast, at foamed cement proportions ranging from 30 to 50%, the peak compressive strength is dominated by foamed cement, with AE energy concentrated around the peak stress. The peak strain of C-FCCS shows a trend of initially increasing and then decreasing with the increase in height ratio (Height ratio = Foamed cement height/C-FCCS height). Under different height ratios, the peak strain of C-FCCS is approximately 175.61-558.13% of that of pure concrete specimens. Furthermore, variations in the strength of foamed cement have a minimal impact on the peak compressive strength of C-FCCS but significantly affect the peak strain. The peak compressive strength of C-FCCS is about 77.67-83.87% of that of pure concrete specimens, while the peak strain ranges from 128.46 to 361.38%. Lastly, the macroscopic failure of C-FCCS is primarily characterized by tensile failure, with shear failure commonly observed at the edges and corner interfaces of C-FCCS.
More Related Videos
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Relation Between Tensile Strength and Compressive Strength of Concrete
Impact Strength of Concrete
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...

