Related Experiment Video
Updated: Sep 17, 2025

Subject-specific Musculoskeletal Model for Studying Bone Strain During Dynamic Motion
Published on: April 11, 2018
Biomechanics associated with bone stress injury in athletes differ by proximal and distal anatomical locations: a
Logan W Gaudette1, Kathryn E Ackerman2,3, Mary L Bouxsein4
1Physical Medicine and Rehabilitation, Spaulding Rehabilitation Hospital, Harvard Medical School, Cambridge, Massachusetts, USA.
Background:
Bone stress injury (BSI) is a common overuse injury in female athletes that can occur in a variety of bones, including both proximal (pelvis, sacrum, femoral neck) or distal (tibia, fibula, metatarsals) locations. Prior work has demonstrated differences in running biomechanics in those with BSI; however, this was not separated by anatomy. We hypothesised that both female athletes with distal BSI and female athletes with proximal BSI would have lower cadence, higher centre of mass (COM) and lower duty factor than those without prior BSI.
Methods:
Cross-sectional study of 45 female athletes (15 with prior distal BSI, 15 with prior proximal BSI and 15 with no BSI history). Each ran on an instrumented treadmill at self-selected and 5-kilometre race speeds, with data collected in a fresh and exerted state. A series of analysis of variance tests (ANOVAs, group by condition) were used to analyse the results.
Results:
Participants with previous proximal BSI ran with greater vertical COM excursion compared with those with no previous BSI at race speed (10.2±1.7 cm vs 8.5±0.8 cm (p<0.001)). The proximal BSI population had a lower cadence than the no prior BSI population at race speed (170±13 steps per minute vs 180±10 steps per minute (p=0.012)). Duty factor was lower in the proximal BSI group compared with the distal BSI group at the race speed (32±3% vs 34±3% (p=0.013)).
Conclusion:
COM and cadence should be further investigated for association with proximal BSI.
More Related Videos
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
06:58Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
Related Concept Videos
Bones of the Lower Limb: Femur and Patella
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Lower Limb: Tibia and Fibula
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...