Related Experiment Video
Updated: Sep 17, 2025

Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Comparison of single-source cardiac CT and CMR quantified ventricular volumes and function in congenital heart
Nikhil Patel1, Jennifer Cohen1, Hari G Rajagopal2
1Department of Pediatrics (Cardiology), Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Background:
Cardiac CT (CCT) is important for anatomic evaluation of congenital heart disease (CHD) prior to pulmonary valve replacement (PVR). However, volumetric and functional criteria for PVR are derived from cardiac MRI (CMR). Systematic differences between CCT and CMR volumes are underexplored in patients with CHD.
Methods:
Retrospective review of CHD patients with CMR and single-source CCT<180 days apart. Ventricular volumes were recontoured by blinded experts and global agreement was compared. Right ventricular regional differences in contours were assessed. Agreement of CCT with CMR-defined criteria for PVR was reported.
Results:
Twenty-nine patients (mean age 33 years, 48 % tetralogy of Fallot, 24 % congenital pulmonary stenosis, 83 % evaluated for PVR) had average CMR RVEDVi 152 mL/m2, RVESVi 80 mL/m2, RVEF 49 %, and RVEDV:LVEDV 1.9:1. CCT measured significantly higher RVEDVi (mean difference (MD) +17 mL/m2), RVESVi (MD +17 mL/m2), and RVEDV:LVEDV (MD +0.1) with no difference in stroke volume. There was a lower RVEF (MD -5 %). CCT had 90-100 % sensitivity/NPV to identify CMR-defined RV PVR thresholds, but had lower specificity and PPV. Faster heart rates had higher RVESVi CCT-CMR difference. The basal and mid-inferior RV contours contributed the most to CCT-CMR differences.
Conclusions:
Single-source CCT measures higher RV volumes and lower EF compared to CMR (i.e. more adversely-remodeled). Mechanisms include inferior stretch due to differences in breathing-instruction, and misidentification of end-systole. CMR-derived PVR thresholds applied to CCT would lead to more proactive intervention. "Adjusting" single-source CCT volumes by the observed difference between modalities is a reasonable approach. Single-source CCT-specific volumetric recommendations for PVR are needed.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Aortic Regurgitation II: Clinical Features and Diagnostic Tests