Factors Influencing Aerosol Delivery During Invasive Ventilation
Fai A Albuainain1,2, Xiaoyan Man3, Omar Alamoudi1
1Mr. Alamoudi and Dr. Li are affiliated with Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, Chicago, Illinois, USA.
None:
Background: Several factors influence aerosol delivery during mechanical ventilation, such as patient characteristics, device configuration, and ventilator settings. This study aimed to evaluate how ventilator settings, humidification, nebulizer positions, bias flows, and circuit adapters affected aerosol delivery during invasive ventilation. Methods: Using an in vitro model, aerosol delivery of albuterol (2.5 mg/3 mL) via a vibrating mesh nebulizer was tested under 28 conditions during invasive ventilation. A systematic stepwise ruling-out approach was taken over 3 phases: (1) dry circuit, (2) dry circuit with exhaled humidity, and (3) heated and humidified circuit with exhaled humidity. Variables included ventilator settings (high vs low), nebulizer positions (proximal to the endotracheal tube vs distal), bias flows (2 vs 5 L/min), and circuit adapters (Y- vs V-shaped). The variables deemed unimportant were progressively excluded in later phases. Each condition was tested 5 times. Drug deposition was collected on filters, eluted, and quantified using ultraviolet spectrophotometry at 276 nm. Results: High ventilator settings significantly increased inhaled doses compared with lower settings across most conditions (all P < .05), with the greatest absolute increase of inhaled dose was observed in dry circuits without exhaled humidity (11-22%). This effect was reduced to 4-7% with the use of exhaled humidity in both dry and heated humidified circuits. Proximal nebulizer placement yielded higher doses than distal placement under high settings in dry circuits without exhaled humidity, but this difference was diminished or absent when exhaled humidity or heated humidification were introduced. Bias flow and adapter type had minimal impact on inhaled dose, except in specific conditions under dry circuit without exhaled humidity. Conclusions: In dry circuits without exhaled humidity, aerosol delivery was substantially affected by ventilator settings and nebulizer placement, whereas bias flow and circuit adapter types had no notable impact. However, the effects of ventilator settings and nebulizer placement diminished in circuits with exhaled humidity or heated humidification.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...