Power management enhancement and smoothing DC voltage using integrated BESS and SMES in Off-grid hybrid AC/DC

Sara Mahmoudi Rashid1, Amir Rikhtehgar Ghiasi2

  • 1Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran.

Scientific Reports
|July 2, 2025
PubMed
Abstract

Related Concept Videos

Generator Voltage Control01:21

Generator Voltage Control

Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
248
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
317
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
267
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
275
Power System Distribution01:25

Power System Distribution

Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
320
Bridge rectifier01:24

Bridge rectifier

The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
857