Related Experiment Video
Updated: Sep 17, 2025

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Direct shoulder MR arthrography using an iron-based positive T1 contrast agent (NEMO-103): comparison of image
Hong Seon Lee1, Chan Woong Jang2, Young Han Lee3
1Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
Abstract:
The need for alternative MR contrast agents in direct shoulder MR arthrography (MRA) arises from limitations associated with gadolinium-based contrast agents (GBCAs), which are deemed "off-label" for MRA and raise concerns about potential toxicity to joint tissue. This study aims to compare the image quality of NEMO-103 (codename)-based and GBCA-based direct shoulder MRA. A total of 89 MRAs from 81 patients were analyzed, with 39 NEMO-103-based MRAs from 31 patients and 50 GBCA-based MRAs from 50 patients. The MRAs were performed at 3.0-T using fast/turbo spin-echo T1- and T2-weighted images with or without fat suppression (spectral presaturation with inversion recovery). Participants included individuals undergoing MRA for suspected or diagnosed shoulder pathologies between August 2021 and September 2022. Quantitative assessments (contrast-to-noise ratio [CNR] and distension measurements) and qualitative evaluations (distension, sharpness, contrast, and overall image quality scores) were conducted by three musculoskeletal radiologists. A visual Turing test (VTT) was used to assess the ability of 39 clinicians to differentiate between the two contrast agents. Statistical tests included the Shapiro-Wilk test, independent t-tests, and chi-squared test. The study compared 31 NEMO-103-based MRAs (11 females [35.5%], age: 40.0 ± 13.0 years) and 38 GBCA-based MRAs (14 females [36.8%], age: 49.4 ± 18.7 years) within 30 min post-injection, and 8 NEMO-103-based MRAs (3 females [37.5%], age: 38.0 ± 7.8 years) versus 12 GBCA-based MRAs (5 females [41.7%], age: 56.2 ± 15.7 years) in the 30-60-min post-injection timeframe. NEMO-103-based MRAs demonstrated superior axillary pouch distension and overall image quality in both comparisons. CNR was notably higher with NEMO-103. The VTT showed a 53.3% accuracy in differentiating NEMO-103 from GBCA, similar to random guessing. NEMO-103 may serve as a potential alternative to GBCAs for direct shoulder MRA, offering comparable or superior image quality with potentially fewer concerns related to gadolinium-associated toxicity.
Insights
NEMO-103 shows promise as a shoulder MR arthrography contrast agent, offering comparable or better image quality than gadolinium-based contrast agents (GBCAs). This alternative may reduce concerns about gadolinium toxicity in joint tissues.
Area of Science:
- Radiology and Imaging
- Musculoskeletal Imaging
- Contrast Agent Development
Background:
- Gadolinium-based contrast agents (GBCAs) are used off-label for direct shoulder MR arthrography (MRA).
- Concerns exist regarding potential GBCA toxicity to joint tissues, necessitating alternative agents.
Purpose of the Study:
- To compare the image quality of direct shoulder MRA using NEMO-103 versus GBCA.
- To evaluate the safety and efficacy of NEMO-103 as a potential GBCA alternative.
Main Methods:
- Retrospective analysis of 89 direct shoulder MRAs (39 NEMO-103, 50 GBCA) at 3.0-T.
- Quantitative (CNR, distension) and qualitative (distension, sharpness, contrast, overall quality) assessments by radiologists.
- Visual Turing Test (VTT) to assess clinician differentiation between contrast agents.
Main Results:
- NEMO-103 demonstrated superior axillary pouch distension and overall image quality compared to GBCAs.
- Contrast-to-noise ratio (CNR) was significantly higher with NEMO-103.
- Clinician accuracy in differentiating NEMO-103 from GBCAs in the VTT was comparable to random chance (53.3%).
Conclusions:
- NEMO-103 offers comparable or superior image quality for direct shoulder MRA.
- NEMO-103 presents a potential alternative to GBCAs with potentially reduced toxicity concerns.
- Further investigation into NEMO-103 for shoulder MRA is warranted.
More Related Videos
11:27Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
13:21Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging