Related Experiment Video
Updated: Sep 17, 2025

Modeling Encephalopathy of Prematurity Using Prenatal Hypoxia-ischemia with Intra-amniotic Lipopolysaccharide in Rats
Published on: November 20, 2015
Association of neonatal and fetal malformations with polyhydramnios and oligohydramnios - introduction of a new
1Department of Obstetrics and Gynecology, Semmelweis University, Budapest, Hungary. beke.artur@semmelweis.hu.
Background:
Our aim was to investigate the association of different neonatal and fetal anatomical abnormalities with polyhydramnios or oligohydramnios during prenatal ultrasonography.
Methods:
In our study, we processed prenatal sonographic and postnatal neonatal clinical and pathological data from 2,622 fetuses with malformations over a 12-year period. We investigated the association of neonatal and fetal abnormalities with polyhydramnios or oligohydramnios. To characterize the prevalence of association between a given disorder and polyhydramnios or oligohydramnios, we used our proprietary "association factor" (AF) for statistical calculations.
Results:
Amniotic fluid volume abnormalities were most frequently detected in urogenital, abdominal, and abdominal wall anomalies. In urogenital anomalies, amniotic fluid volume abnormalities were found in more than half of the fetuses, 54.86% (oligohydramnios 34.72%, polyhydramnios 20.14%). In abdominal and abdominal wall anomalies, 43.82% of fetuses had abnormalities in the volume of amniotic fluid (polyhydramnios 31.44%, oligohydramnios 12.38%). Overall, we found abnormalities in the volume of amniotic fluid in over 30% of the fetuses with craniospinal, thoracic and pulmonary anomalies, limb anomalies, and ossification disorders. In craniofacial and cardiovascular anomalies, amniotic fluid volume abnormalities were only detectable in around 20%. For polyhydramnios, the "Association Factor" (AF) was very high for craniospinal, abdominal, and abdominal wall disorders, and it was high for cardiovascular, urogenital, limb, and ossification disorders. For oligohydramnios, the association factor (AF) was very high for urogenital disorders.
Conclusions:
If the amniotic fluid volume during ultrasonography is less or more than average, special attention should be paid to the ultrasound examination of the fetus' urogenital system, abdominal organs, skull, spine, chest, lungs, as well as limbs and skeletal system. In the case of polyhydramnios, fetal echocardiography is recommended.
More Related Videos
Related Concept Videos
Teratogenicity
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility,...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Neurulation

