Related Experiment Video
Updated: Sep 17, 2025

Acquisition and Semi-Automated Analysis of Respiratory Muscle Surface Electromyography
Published on: January 24, 2025
Respiratory effort monitoring: a novel, bedside, non-invasive, real-time method
Yinxia Lv1, Meiling Dong1, Haisong Song2
1Department of Respiratory Care, West China Hospital of Sichuan University, Chengdu, 610041, China.
Background:
Mechanical ventilation is essential for treating respiratory failure. However, ventilator over-assistance can lead to ventilator-induced diaphragm dysfunction (VIDD), and insufficient assistance can necessitate excessive effort, which leads to high stress and damage diaphragm function. Current methods monitoring respiratory effort face clinical implementation challenges due to invasiveness and complexity. This study introduces and validates a novel non-invasive real-time respiratory muscle pressure (N-Pmus) monitoring method.
Methods:
(1) The bench study involved developing a non-invasive, real-time respiratory muscle pressure monitoring algorithm (N-Pmus) based on the equation of motion of the respiratory system and validated with efforts generated by the ASL simulator (ASL5000-Pmus) across 270 clinical scenarios. (2) A clinical validation was performed through a prospective observational study (n = 23), comparing N-Pmus with the Pmus derived from simultaneously monitored esophageal pressure (Pmuseso) to assess correlation and agreement. The association between N-Pmus and the established Pmus benchmarks was analyzed using linear mixed-effects models. Bias and agreement were evaluated through Bland-Altman analysis for repeated measures.
Results:
(1) The bench study demonstrated that N-Pmus correlated well with ASL5000-Pmus, with marginal R²=0.993 and conditional R²=0.997. The bias was - 0.23 cmH₂O, with limits of agreement ranging from - 1.51 to 1.04 cmH₂O. (2) The clinical validation revealed strong N-Pmus/Pmuseso agreement with marginal R²=0.97 and conditional R²=0.971. The bias was - 0.2 cmH₂O, with limits of agreement ranging from - 2.22 to 1.83 cmH₂O.
Clinical Trial Number:
Retrospectively registered with https://www.chictr.org.cn/ .
Registration Number:
ChiCTR2300076940, registered 24 October 2023.
More Related Videos
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...

