Staphylococcus aureus Strains With a Negative Coagulase Tube Test are Associated With Staphylocoagulase Genotypes
Carly L Botheras1,2,3, Dieter Bulach3,4, Eugene Athan1,2,5
1Centre for Innovation in Infectious Disease and Immunology Research (CIIDIR), School of Medicine, Deakin University, Geelong, VIC 3220, Australia.
Frontiers in Bioscience (Scholar Edition)
|July 4, 2025
Summary
Certain Staphylococcus aureus strains may incorrectly test negative in the coagulase tube test due to specific coagulase genotypes. This finding impacts diagnostic accuracy for identifying this significant human pathogen.
Area of Science:
- Microbiology
- Clinical Diagnostics
- Genomics
Background:
- Staphylococcus aureus is a major human pathogen requiring accurate identification.
- Differentiating S. aureus from coagulase-negative staphylococci is crucial in diagnostics.
- The coagulase tube test is a preliminary identification method, but can yield false negatives.
Purpose of the Study:
- To investigate why some S. aureus isolates test negative in the coagulase tube test.
- To determine if specific coagulase (coa) genotypes are associated with false-negative results.
- To assess the clinical impact of false-negative coagulase tube test results.
Main Methods:
- Whole genome sequencing was used to determine coa genotypes of 122 clinical S. aureus bloodstream isolates.
- Analysis of genomic regions flanking the coa gene for regulatory differences.
- Reverse transcription quantitative real-time PCR (RT-qPCR) assessed coa gene expression in a subset of isolates.
Main Results:
- All 122 isolates possessed the coa gene; 18.9% tested negative in the coagulase tube test.
- No association was found between negative tube test results and complicated bloodstream infections.
- Staphylocoagulase types X and XI isolates were more likely to yield negative tube test results despite having functional coa genes.
Conclusions:
- Specific S. aureus lineages, particularly ST15 and ST3911 (staphylocoagulase genotype X), may test negative in the coagulase tube test.
- The observed negativity is attributed to the inability of certain coagulase types to clot the commercial test substrate.
- This has significant implications for the reliability of the coagulase tube test in routine diagnostics.