An improved YOLOv7-Tiny method for liquid level detection in medical infusion monitoring
Yonghu Chang1, Changwen Pu1, Shijie Li2
1School of Medical Information Engineering, Zunyi Medical University, Zunyi 563000, China.
Background:
Intravenous infusion is a common medical intervention, but the need for constant monitoring of fluid levels increases the psychological burden on patients and the workload on healthcare providers. Intelligent infusion monitoring systems can address these issues by providing real-time alerts when the fluid level is low. However, existing methods struggle with accuracy and adaptability in detecting fluid levels under complex conditions.
Methods:
This study proposes an improved YOLOv7-tiny-based method for liquid level detection in medical infusion monitoring. To improve performance, three novel modules built upon the Extended Layers Aggregation Network (ELAN)-Dynamic Snake Convolution (DS)-ELAN, Deformable Convolution Network (DCN)-ELAN, and Partial Convolution (P)-ELAN-are proposed. These modules are designed to enhance detection accuracy for elongated structures, adapt to shape variations, and optimize computational efficiency for deployment on edge devices. The proposed method was trained on a dataset of 4296 annotated infusion bottle images captured under diverse lighting and environmental conditions. Performance was evaluated using metrics such as recall, mean average precision (mAP), and inference speed.
Results:
Experimental results demonstrate that the improved YOLOv7-tiny method achieves superior performance compared to the baseline YOLOv7-tiny, with a recall of 88.319% and mAP@[0.5:0.95] of 90.102%, while maintaining comparable computational complexity. Ablation studies confirm the independent contributions of each proposed module to the overall performance. The enhanced method also shows robust real-time capability on embedded devices.
Conclusion:
The proposed method significantly improves the accuracy and usability of intelligent infusion monitoring systems, enabling real-time detection of fluid levels in medical infusion bottles. This approach reduces the workload on healthcare providers, minimizes patient risks, and demonstrates potential for broader applications in medical monitoring scenarios.
More Related Videos
Related Concept Videos
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Rise of Liquid in a Capillary Tube
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...