Related Experiment Video
Updated: Jul 3, 2026

Robotic Left Hepatectomy using Indocyanine Green Fluorescence Imaging for an Intrahepatic Complex Biliary Cyst
Published on: June 24, 2022
Multicenter validation of a cholangioscopy artificial intelligence system for the evaluation of biliary tract disease
Neil Marya1,2, Patrick Powers1,2, Jad P AbiMansour3
1Gastroenterology, UMass Chan Medical School, Worcester, United States.
Background:
Clinicians struggle to accurately classify biliary strictures as benign or malignant. Current endoscopic retrograde cholangiopancreatography (ERCP)-based sampling modalities including brush cytology and forceps biopsy have poor sensitivity for pathologic confirmation of malignancy. Cholangioscopy allows for direct visualization and sampling of biliary pathology; however, this technology is also associated with inaccurate classification of biliary disease. Previously, an artificial intelligence (AI) system that analyzes cholangioscopy footage was found to be more accurate in diagnosing biliary malignancy than ERCP sampling techniques. The aim of this study was to validate this AI system on a new series of examinations.
Method:
Three academic centers collected all available unedited cholangioscopy recordings. The videos were processed by the cholangioscopy AI system. After analyzing videos, the AI system provided predictions as to whether malignancy was present. AI performance in classifying strictures was compared with the performance of brush cytology and forceps biopsy.
Results:
112 cholangioscopy examinations (containing 4 817 081 images) were generated from 99 patients. Of those examinations, 61 (54.5%) were for investigation of biliary strictures (31 [50.8%] benign, 30 [49.2%] malignant). For the correct classification of strictures, the AI system was 80.0% sensitive and 90.3% specific. It was also significantly more accurate for stricture classification (85.2%) than brush cytology (52.5%; P<0.001), forceps biopsy (68.2%; P=0.04), and the combination of brush cytology and forceps biopsy (66.7%; P=0.02).
Conclusion:
A previously developed cholangioscopy AI system was found to continually outperform standard ERCP sampling modalities for accurate identification of malignancy, without additional retraining, in a multicenter validation cohort.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies I: Kidney, Ureter, and Bladder Studies
