Related Experiment Video
Updated: Sep 16, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Feasibility and Confidence in Carotid Spectral Doppler for Pulse Detection: Training Outcomes Among Emergency
Jeremy Carter1, Connor Babbush2, Ian Coe3
1Emergency Medicine, University of Texas Medical Branch, Galveston, USA.
Abstract:
Introduction Carotid ultrasound has demonstrated utility in identifying the presence of a pulse, particularly in cardiac arrest. Despite this evidence, there is currently no existing literature that focuses on the training of physicians in this modality for the purpose of pulse detection. The primary objective of this study is to demonstrate that novice ultrasound users with varying levels of training can be taught a simple and repeatable method for identifying flow in the common carotid artery (CCA) using a combination of B-mode ultrasound and spectral Doppler. The secondary objective is to evaluate the confidence of emergency medicine (EM) residents with varying levels of ultrasound experience in accurately identifying the carotid pulse using spectral Doppler. Methods This is a cross-sectional study, using a convenience sample of emergency medicine (EM) residents. Residents with varying levels of ultrasound experience received training on obtaining CCA ultrasound images and spectral Doppler. Subjects were then asked to image the common carotid artery and obtain a spectral Doppler waveform on a standardized patient. Expert sonologists observed participants' imaging in real time and recorded their performance. Participants completed a post-questionnaire detailing the number of previous ultrasound examinations they had performed and their comfort level with the carotid ultrasound technique. Results Thirty-eight residents participated in the study. The residents were able to obtain a spectral Doppler waveform from the CCA in 38 (100%) of cases, and 35 (92%) residents were able to perform this task without any assistance from the instructor. The average time to obtain a waveform was 23 seconds. Twelve (32%) residents were able to obtain a pulse within 15 seconds. After the training session, 37 (97%) residents felt comfortable identifying arterial flow in the CCA using spectral Doppler and would feel comfortable using this technique on an actual patient receiving cardiopulmonary resuscitation (CPR). Conclusion Spectral Doppler of the CCA may be a reasonable alternative for identifying return of spontaneous circulation (ROSC) during pulse check of patients receiving CPR. All residents were able to identify pulses using spectral Doppler, following a brief lecture, instructional video, and hands-on training session.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring pulse
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse
The pulse serves as a clinical...
Pulse Assessment Sites

