Related Experiment Video
Updated: Sep 16, 2025

Author Spotlight: Advancements in 3D Optical Imaging for Comprehensive Body Composition Assessment in Modern Research
Published on: June 7, 2024
A predictive model for body water and fluid balance using 3D smartphone anthropometry
Austin J Graybeal1, Abby T Compton1, Sydney H Swafford1
1School of Kinesiology and Nutrition, University of Southern Mississippi, Hattiesburg, MS, United States.
Background:
Body fluid volumes, including total body water (TBW), extracellular fluid (ECF), and intracellular fluid (ICF), are crucial indicators of body composition, and the distribution of these fluids is essential for assessing hydration status and fluid accumulation. Although fluid volumes are commonly measured with bioelectrical impedance devices, several challenges hinder the application of this technique. However, 3D smartphone scanning applications that automate body volumes and other anthropometric estimates may provide a viable alternative to body fluid assessments.
Methods:
A total of 338 participants underwent fluid volume assessments using bioelectrical impedance spectroscopy (BIS) and collected body volumes and anthropometric data using a 3D smartphone scanning application. Then, LASSO regression was used to develop new TBW and ECF prediction model in a subset of participants (n = 272), which was subsequently tested in the remaining participants (n = 66). Smartphone-derived ICF was calculated as the difference between smartphone-predicted TBW and ECF. Fluid overload and imbalance were determined using ECF/TBW and ECF/ICF, respectively, and subsequently predicted from the retained variables using receiver operating characteristic curve analyses and logistic regression.
Results:
Estimates from each of the newly-developed prediction models were not significantly different from the estimates produced using BIS (all p ≥ 0.70) and revealed acceptable agreement (TBW: R 2 = 0.91, RMSE = 3.24 L; ECF: R 2 = 0.94, RMSE = 1.10 L; ICF: R 2 = 0.87, RMSE = 2.29 L) when evaluated in the testing sample (n = 66), although proportional bias was observed (p < 0.001). Smartphone-predicted fluid overload (AUC: 0.81 [95%CI: 0.70, 0.92]; sensitivity + specificity: 1.53 [95%CI: 1.39, 1.67]) and imbalance (AUC: 0.76 [95%CI: 0.64, 0.88]; sensitivity + specificity: 1.40 [95%CI: 1.24, 1.56]) demonstrated acceptable diagnostic performance.
Conclusion:
Smartphone scanning applications can accurately assess body fluid volumes and imbalances, presenting new possibilities for health screening beyond clinical environments.
Related Concept Videos
Body Water Content and Fluid Compartments
Regulation of Water Intake
Disorder of Water Balance
Dehydration
Dehydration occurs when the body loses fluids (particularly water).
Causes:
The major causes of dehydration include excessive sweating, fever, vomiting, diarrhea, and diuresis.
Signs and Symptoms:
Symptoms primarily include intense...
Composition of Body Fluids
Typical Model Studies