Related Experiment Video
Updated: Sep 16, 2025

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
Published on: October 24, 2018
Endotoxin removal by the OXIRIS filter for cardiogenic shock requiring veno-arterial extra-corporeal life support:
Maxime Nguyen1,2,3, Marvin Alvarez4, Corentin Evezard5
1Department of Anesthesiology and Intensive Care, Dijon University Hospital, Dijon, France. maxime.nguyen-soenen@chu-dijon.fr.
Background:
Most severe cardiogenic shock requires veno-arterial extracorporeal membrane oxygenation (VA-ECMO). The OXIRIS filter, has shown potential in reducing lipopolysaccharide (LPS) levels. Our objective was to compare the efficacy of the OXIRIS filter versus the ST-150 filter in reducing LPS plasma concentration. We hypothesized that the OXIRIS filter would reduce the endotoxin burden.
Methods:
We conducted an open-label randomized prospective study in the cardiac intensive care unit of Dijon University Hospital. Forty patients with refractory cardiogenic shock requiring VA-ECMO and renal replacement therapy (RRT) were randomized to receive either OXIRIS filter or ST-150 filter. Blood samples were collected at multiple time points. The primary outcome was LPS mass (measured 24 h after the initiation of treatment). Secondary outcomes included LPS activity, cytokine levels, and clinical outcomes.
Results:
20 patients were allocated to each group and analyzed. LPS plasma concentrations were not different between the OXIRIS filter and ST-150 filter groups at H24 (599 pmol/ml of esterified 3-OH fatty acids [450;734] vs 520 [456;835], p = 0.983) or when analyzing all time-points by linear mixed modelling (538 [469;723] vs 507 [434;671] at H26, 576 [513;614] vs 624 [503;724] at H48 and 632 [513;660] vs 586 [538;776] at H72, p = 0.882). No significant between groups differences were found in LPS activity, inflammation markers (IL-6, TNF-α, IL-10, MCP-1), SOFA scores, VIS scores, or 28-day mortality (13 (65%) vs 9 (45%) p = 0.21). There was high variability in LPS concentrations, suggesting heterogeneity in endotoxemia.
Conclusions:
In patients with cardiogenic shock supported by VA-ECMO and requiring renal replacement therapy, we could not evidence any reduction in LPS blood concentration in patients treated with treatment with OXIRIS filter in comparison to ST-150 filter. Further research is required to confirm these findings and optimize endotoxin removal in this population.
Trials Registration:
NCT04886180. Registered 10 May 2021.
More Related Videos
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
07:41Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Related Concept Videos
Continuous Renal Replacement Therapy
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...