Comprehensive evaluation of angiography Equipment: Ensuring precision and compliance in high-precision medical
1Cicanum, Universidad de Costa Rica, UCR, San José, Costa Rica.
Abstract:
This comprehensive study studies the detailed assessment of angiography devices in high-precision medical interventions. Concentrating on geometric parameters, metrology, dosimetry, performance, and image quality, it holds all the requirements and ideals established by the regulatory authority in Costa Rica. The verification was meticulously conducted, encompassing geometrical parameters such as the source-to-skin distance, X-ray beam perpendicularity and centering, image detector input field size, geometric distortion, monitor linearity, and alignment of the radiation field with the detector's field of view.The results confirmed that the equipment fully complies with the stringent requirements established by regulatory standards. Operationally, the system was evaluated at different peak kilovoltage (kVp) settings -60 kVp, 80 kVp, 90 kVp, and 110 kVp-in pulsed fluoroscopy mode, with precisely defined pulse durations and frequencies. The performance evaluation included analysis of output consistency (μGy·m2/mAs), tube current (mA) and time (s), as well as additional non-invasive tests on the generator. The results demonstrated stable performance within permissible limits. The assessment also covered peak kilovoltage accuracy and beam filtration, confirming compliance with applicable regulatory standards. Image quality was critically evaluated, with particular attention to the presence of artifacts and spatial resolution, which remained within the established acceptable thresholds. Additionally, a radiometric study was conducted to illustrate the distribution of the radiation field around the examination table and other areas of interest. This complementary analysis reinforces the overall evaluation of the angiography system, providing assurance of its clinical suitability and operational safety. The specific findings indicate that the pulse duration and pulse rate were 133.7 ms and 4 pulses per second, respectively. These values will serve as the reference standard for a future angiographic operating under similar conditions, with a beam filtered by 4.9 mm Al. The measured dose output was 49.3 μGy m2/mAs, with a maximum deviation of 3.9 %. The peak kilovoltage showed a deviation of only 0.7 %. Image quality was free of artifacts, with a measured spatial resolution (line pairs per millimeter) of 5 lp/mm and a detection threshold of 2.5 lp/mm. Overall image uniformity reached 96 %. A radiation field distribution map accurately depicts the spatial characteristics of the room. In summary, the results demonstrate that this equipment not only meets but, in some aspects, exceeds established standards of practice, highlighting the importance of comprehensive evaluation in this field.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
05:26Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization I: Pre-Procedure Overview
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Imaging Studies for Cardiovascular System V: CT