Related Experiment Video
Updated: Jul 11, 2026

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
AI-enhanced patient-specific dosimetry in I-131 planar imaging with a single oblique view
Mostafa Jalilifar1, Mahdi Sadeghi2, Alireza Emami-Ardekani3
1Department of Radiologic Technology, School of Allied Medical Sciences, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
Abstract:
This study aims to enhance the dosimetry accuracy in 131I planar imaging by utilizing a single oblique view and Monte Carlo (MC) validated dose point kernels (DPKs) alongside the integration of artificial intelligence (AI) for accurate dose prediction within planar imaging. Forty patients with thyroid cancers post-thyroidectomy surgery and 30 with neuroendocrine tumors underwent planar and SPECT/CT imaging. Using whole-body (WB) planar images with an additional oblique view, organ thicknesses were estimated. DPKs and organ-specific S-values were used to estimate the absorbed doses. Four AI algorithms- multilayer perceptron (MLP), linear regression, support vector regression model, decision tree, convolution neural network, and U-Net were used for dose estimation. Planar image counts, body thickness, patient BMI, age, S-values, and tissue attenuation coefficients were imported as input into the AI algorithm. To provide the ground truth, the CT-based segmentation generated binary masks for each organ, and the corresponding SPECT images were used for GATE MC dosimetry. The MLP-predicted dose values across all organs represented superior performance with the lowest mean absolute error in the liver but higher in the spleen and salivary glands. Notably, MLP-based dose estimations closely matched ground truth data with < 15% differences in most tissues. The MLP-estimated dose values present a robust patient-specific dosimetry approach capable of swiftly predicting absorbed doses in different organs using WB planar images and a single oblique view. This approach facilitates the implementation of 2D planar imaging as a pre-therapeutic technique for a more accurate assessment of the administrated activity.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET