Related Experiment Video
Updated: May 6, 2026

Haptic/Graphic Rehabilitation: Integrating a Robot into a Virtual Environment Library and Applying it to Stroke Therapy
Published on: August 8, 2011
Smartwatch-based wrist tremor assessment in neurosurgical simulator training
Laurenz Berger1,2, Lorenzo Civilla3,4, Philippe Dodier5
1Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria. laurenz.berger@meduniwien.ac.at.
None:
While surgical skill is acquired during training, objectively evaluating training's impact is challenging. However, new possibilities in measuring wrist tremor during surgical procedures have emerged due to novel wearable sensors. In this study, the effect of simulator-based neurosurgical resident training on wrist tremor was assessed using a smartwatch. A study involving nine neurosurgical residents performing simulator-based training on unruptured intracranial aneurysm clipping procedures was conducted. Residents performed four training sessions on two days (180 clippings in total). Three cohorts were formed receiving in between the two days either: no training, video-based training, or video-based training with augmented reality. Wrist acceleration was measured using a smartwatch. Wrist tremor was calculated using the acceleration data in time and frequency domains (peak power, total power, and peak frequency). Video-based training with augmented reality showed a statistically significant reduction in total power as well as in peak power, with reductions of 56% (p = 0.0186) and 69% (p = 0.0021), between day 0 and day 14, respectively. Wrist tremor assessment using a smartwatch confirmed the positive impact of video-based and augmented reality training on neurosurgical residents' confidence in surgical training procedures by reducing wrist tremor, making it a valuable tool for skill assessment.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...

