A Prediction Model of Stable Warfarin Doses in Patients After Mechanical Heart Valve Replacement Based on a Machine
Bowen Guo1, Cong Chen1, Junhang Jia1
1Center of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, 100000 Beijing, China.
Background:
The narrow therapeutic range of warfarin, alongside the response of numerous influencing factors and significant inter-individual variability, presents major challenges for personalized medication. This study aimed to combine clinical and genetic characteristics with machine learning (ML) algorithms to develop and validate a model for predicting stable warfarin doses in patients from Northern China after mechanical heart valve replacement surgery.
Methods:
This study included patients who underwent mechanical heart valve replacement surgery at the Beijing Anzhen Hospital between January 2021 and January 2024 and achieved a stable warfarin maintenance dose. Comprehensive clinical and genetic data were collected, and patients were divided into training and validation cohorts at an 8:2 ratio through random division. The variables were selected using analysis of covariance (ANCOVA). Algorithms for predicting the stable warfarin dose were constructed using a traditional linear model, general linear model (GLM), and 10 ML algorithms. The performance of these algorithms was evaluated and compared using R-squared (R2), mean absolute error (MAE), and ideal prediction percentage to identify the optimal algorithm for predicting the stable warfarin dose and verify its clinical significance.
Results:
A total of 413 patients were included in this study for model training and validation, and 13 important features were selected for model development. The support vector machine radial basis function (SVM Radial) algorithm showed the best performance of all models, with the highest R2 value of 0.98 and the lowest MAE of 0.14 mg/day (95% confidence interval (CI): 0.11-0.17). This model successfully predicted the ideal warfarin dose in 93.83% of patients, with the highest ideal prediction percentage found in the medium-dose group (95.92%). In addition, the model demonstrated high predictive accuracy in both the low-dose and high-dose groups, with ideal prediction percentages of 85.71% and 92.00%, respectively.
Conclusions:
Compared to previous methods, SVM Radial demonstrates significantly higher accuracy for predicting the warfarin maintenance dose following heart valve replacement surgery, suggesting it has potential for widespread application. However, this study was based on a relatively small sample size and conducted at a single center. Future research should involve larger sample sizes and multicenter data to validate the predictive accuracy of the SVM Radial model further.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
07:46Author Spotlight: Revolutionizing Remote Surgery with Augmented Reality and Robotics for Enhanced Precision and Accessibility
Published on: August 9, 2024
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Mitral Valve Prolapse II: Assessment and Management
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...