Related Experiment Video
Updated: Sep 16, 2025

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
A novel immunoprecipitation-based targeted liquid chromatography-tandem mass spectrometry analysis for accurate
Danni Mu1, Xiaoli Ma1, Yichen Ma1
1Department of Laboratory Medicine, 34732 Peking Union Medical College Hospital , Peking Union Medical College and Chinese Academy of Medical Science, Beijing, 100730, China.
Objectives:
Copeptin, a stable and simple-to-measure surrogate marker for arginine vasopressin (AVP), demonstrates excellent clinical values, particularly in diagnosing polyuria-polydipsia syndromes. However, conventional immunoassay methods are limited and lack comparability. Our aim was to establish a targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying copeptin in human serum.
Methods:
Copeptin was extracted from serum using immunoprecipitation, digested with trypsin, and prepared using anion exchange solid-phase extraction before LC-MS/MS detection. The analytical performance was validated in accordance with current guidelines. The method was compared to an immunofluorescent assay on the B.R.A.H.M.S platform.
Results:
The LC-MS/MS method had a runtime of 8.5 min. The within-run precision ranged from 5.2 to 12.1 %, and total coefficients of variation ranged from 8.1 to 13.5 %. Copeptin quantitation showed linearity within the range of 5-1,000 pg/mL, with a limit of detection of 2.5 pg/mL. Recovery rates ranged from 95.2 to 103.1 %, and no significant matrix effect was observed with internal standard correction. The LC-MS/MS method had a good consistency with the immunoassay (r=0.926, slope=0.989). The reference interval for healthy individuals was 3.66-58.25 pg/mL.
Conclusions:
We demonstrated the accuracy and reliability of this targeted LC-MS/MS method for quantifying copeptin. This innovative application showed satisfactory precision, a wide linear range, and a low limit of detection. Clinical studies are anticipated to be conducted to assess diagnostic accuracy using this method.
More Related Videos
08:12Utilizing a Comprehensive Immunoprecipitation Enrichment System to Identify an Endogenous Post-translational Modification Profile for Target Proteins
Published on: January 8, 2018
10:21Microsampling in Targeted Mass Spectrometry-Based Protein Analysis of Low-Abundance Proteins
Published on: January 13, 2023
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...