Related Experiment Video
Updated: Sep 16, 2025

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Non-contact (touchless) monitoring of respiratory rate in a challenging anesthesia setting using a depth camera
David B MacLeod1, Philip Smit2, André Antunes2
1Department of Anesthesiology, Duke University Medical Center, Durham, NC, 27710, US.
Aim:
We have developed a non-contact ("touchless") system based on depth-sensing camera technology for continuous monitoring of respiratory activity. Previous work from our group has demonstrated high accuracy of the system in monitoring a wide range of respiratory rates and signal morphologies across diverse conditions, including variations in lighting, posture, and coverings. Here, we report on the system's performance in a significantly more challenging anesthesia environment which included a wide range of respiratory rates and respiratory patterns, spontaneous and hand ventilated breathing, patient motion and caregiver interactions in the scene, and, in some cases, the presence of warming blankets covering the torso.
Methods:
Data was collected opportunistically from 34 healthy volunteers from two separate studies, both of which had the primary objective of investigating the relationship between depth of anesthesia monitoring and anesthetic agents (inhaled and intravenous) across a wide range of anesthetic concentrations and hypnotic states. Depth-sensing information was acquired using an Intel D415 RealSense™ camera and processed to extract frame-by-frame depth changes within the subject's torso region corresponding to respiratory activity. A respiratory rate (RRdepth) was calculated and output once-per-second from the device. This was compared to a combined reference (RRref) derived from both a capnograph and an impedance-based respiratory monitor. Three time periods were evaluated: pre-anesthesia, intra-anesthesia and post-anesthesia.
Results:
The overall RMSD accuracy [bias] obtained for the combined data set was 1.92 [0.30] breaths/min. The performance results stratified according to pre-, intra-, and post-anesthesia stages were 1.71 [0.15], 1.95 [0.39] and 2.13 [0.08] breaths/min, respectively.
Conclusions:
We have demonstrated the ability to continuously track respiratory rate during challenging conditions within an anesthesia setting using our non-contact, touchless, monitoring technology. We believe that our findings support the potential utility for continuous non-contact monitoring of respiration in clinical areas, such as the post-anesthesia care environment.
More Related Videos
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...