Bedside Assessment of Downgaze Limit by Amplitude
Tao Xie1, Mahesh Padmanaban1, John Collins2
1Department of Neurology, The University of Chicago, Chicago, IL, USA.
Background:
Bedside assessment of downgaze palsy could be difficult, due to the lack of a marker to differentiate normal from palsy, which could delay the diagnosis of progressive supranuclear palsy (PSP). Amplitude based bedside assessment using the intercanthal line as a marker was reported to easily identify, quantify, and record downgaze limit by any smartphone. However, further assessment is needed.
Objective:
To study the reliability of this method in assessing downgaze limit.
Methods:
We assessed downgaze limit by amplitude in 36 healthy controls (HC), 50 patients with Parkinson's disease (PD), and 23 with probable PSP when they strived to look down. We also checked the intra-rater agreement in another 18 patients with probable PSP by a neurologist, inter-rater agreement between two neurologists, and intra-rater agreement between visual estimation and smartphone acquired eye imaging based quantification in probable PSP, PD, and HC. The association between the extent of downgaze palsy and brain atrophy in MRI was also evaluated in patients with probable PSP.
Results:
None of the 86 non-PSP subjects had upper edges of the iris above the intercanthal line (downgaze palsy absent), while the 41 patients with probable PSP all had upper edges of the iris above the intercanthal line (downgaze palsy present). We also found a high intra-rater agreement by a neurologist, inter-rater agreement between two neurologists, intra-rater agreement between visual estimation and imaging quantification, and association between the extent of downgaze palsy and brain atrophy.
Conclusions:
This study supports this bedside assessment, with significant clinical and research applications.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.