Related Experiment Video
Updated: Sep 16, 2025

Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
Accurate Fick cardiac output estimation: direct and simultaneous oxygen consumption measurement is imperative in
Marlus Karsten1, Carlo Vignati2, Beatrice Pezzuto3
1Cardiovascular Health and Exercise Research Group (GEPCardio), Department of Physiotherapy, Graduate Program in Physiotherapy, Santa Catarina State University (UDESC), Florianopolis, Santa Catarina, Brazil; Centro Cardiologico Monzino, IRCCS, Milan, Italy; Department of Clinical Sciences and Community Health, Cardiovascular Section, University of Milan, Milan, Italy.
Background:
Estimated oxygen consumption (VO2) values may compromise the accuracy of the Fick method for predicting cardiac output (CO) during a right heart catheterization (RHC). We aimed to compare VO2 measured in the hemodynamic laboratory (HL) with those measured on the ward or estimated, and to compare derived CO values with that obtained by thermodilution (TD) in people with severe heart failure (HF).
Methods And Results:
In this prospective observational study, VO2 was measured breath-by-breath in the HL and in the ward (within 24h of RHC), or estimated using formulas. CO was calculated from both estimated and measured VO2 and assessed by TD. Eighty individuals with HF (69.6 ± 8.3 years; 74% male) were included. Significant differences were found between HL-measured VO2 (247 ± 55 mL/min), ward-measured VO2 (267 ± 74 mL/min), and the estimated values (Bergstra: 287 ± 33; Dehmer: 234 ± 24; LaFarge: 163 ± 11 mL/min). CO calculated from HL-measured VO2 (5.03 ± 1.51 L/min) differed from CO based on ward-measured VO2 (5.46 ± 1.93 L/min), estimated VO2 (Bergstra: 5.85 ± 1.38; Dehmer: 4.77 ± 1.12; LaFarge: 3.34 ± 0.80 L/min), and by TD (3.65 ± 1.22 L/min). Measured and estimated VO2 values showed moderate association (r values range: 0.479-0.526). CO calculated from HL-measured VO2 showed higher association (r values range: 0.708-0.765) with CO calculated from ward-measured VO2 and estimated VO2. The agreement between HL and ward-measured VO2 was moderate, with a concordance correlation coefficient of 0.48 (0.31;0.62).
Conclusions:
In people with severe HF undergoing RHC, VO2 must be directly measured in the HL, rather than on the ward or estimated.
More Related Videos
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...