Temporal evidence fusion evaluation method considering time sequence variation trend
Sunan Zhang1, Yanxin Gao2, Yuanchao Kou3
1Engineering Training Center, Taiyuan Institute of Technology, Taiyuan, 030008, China. zhangsn@tit.edu.cn.
None:
Aiming at the temporal information fusion evaluation problem, a temporal evidence fusion evaluation method was proposed by considering the time sequence trend based on evidence theory to fully reflect the dynamic trend of temporal information and the influence of the time factor on fusion evaluation. Firstly, the trend of temporal evidence sequence was integrated into fusion evaluation. The temporal variation factor of the proposition was defined by analyzing the sequence of changes in evidence to measure the dynamic of the proposition. Then, conflict information between evidence was interpreted as the temporal variation information of propositions. An evidence combination rule integrating temporal variation factors of propositions was proposed in this paper. Finally, the proposed method was used to fuse and evaluate the temporal evidence. The consecutive periodic health assessment data were utilized to validate the fusion results. Numerical examples show that the discrepancy between the combined BPAs obtained using the proposed method is significantly larger, while the associated uncertainty is notably reduced. The proposed method is capable of handling conflicting information within a temporal information sequence and obtaining a reasonable fusion evaluation result by combining the temporal variation trend of propositions. It provides an idea for information fusion evaluation considering the time sequence trend.
Related Concept Videos
Time-Series Graph
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Correlation of Experimental Data
For example, a spherical particle moving through a viscous fluid experiences drag. Dimensional analysis shows that the drag force depends on the particle's diameter, velocity,...
Per-Unit Sequence Models
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...


