Related Experiment Video
Updated: Sep 16, 2025

A Simple, Low-cost, and Robust System to Measure the Volume of Hydrogen Evolved by Chemical Reactions with Aqueous Solutions
Published on: August 17, 2016
Raman Gas Sensor for Hydrogen Detection via Non-Dispersive and Dispersive Approaches
Fabio Melison1, Lorenzo Cocola1, Luca Poletto1
1National Research Council of Italy, Institute for Photonics and Nanotechnologies, CNR-IFN, Via Trasea 7, 35131 Padova, Italy.
None:
The current solicitude in hydrogen production and its utilization as a greenhouse-neutral energy vector pushed deep interest in developing new and reliable systems intended for its detection. Most sensors available on the market offer reliable performance; however, their limitations, such as restricted dynamic range, hysteresis, reliance on consumables, transducer-sample interaction, and sample dispersion into the environment, are not easily overcome. In this paper, a non-dispersive Raman effect-based system is presented and compared with its dispersive alternative. This approach intrinsically guarantees no sample dispersion or preparation, as no direct contact is required between the sample and the transducer. Moreover, the technique does not suffer from hysteresis and recovering time issues. The results, evaluated in terms of sample pressures and camera integration time, demonstrate promising signal-to-noise ratio (SNR) and limit of detection (LOD) values, indicating strong potential for direct field application.
More Related Videos
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Gas Chromatography: Types of Detectors-II
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...