Related Experiment Video
Updated: Sep 15, 2025

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
The influencing factors of neonatal extubation failure: A systematic review and meta-analysis
Hengyang Wang1, Donghui Jia1, Qian Wang1
1The First Hospital of Lanzhou University, Lanzhou, Gansu, 730000, PR China; School of Nursing, Lanzhou University, Lanzhou, Gansu, 730000, PR China.
Objective:
To assess risk factors for extubation failure in mechanically ventilated neonatal patients in the neonatal intensive care unit.
Methods:
We conducted a systematic review and meta-analysis of the literature. Data are reported as pooled odds ratios for categorical variables and mean differences for continuous variables. Data were sourced from common databases.
Results:
A total of 3152 studies were retrieved, 22 of which were included in this meta-analysis involving 4096 children. The risk factors identified were: male sex, low gestational age, low body weight, low 1-min Apgar score and 5-min Apgar score, airway abnormality, necrotizing enterocolitis, diaphragmatic paralysis, sternal closure delay, patent ductus arteriosus, low pH, highPaCO2, low PaO2, low PaO2/FiO2, low white blood cell count, high heart rate, prolonged length of MV, inhaled nitric oxide and prolonged length of stay in the NICU. Subgroup analysis showed distinct risk factors for extubation failure among preterm, term, surgical, and non-surgical neonates. Within 48 or 72 h of extubation, risk factors mostly overlapped, highlighting the need for tailored extubation strategies.
Conclusions:
We identified 20 factors associated with an increased risk of extubation failure, which can help medical staff in the early identification of children with high risk of extubation failure and thereby take measures. Future studies could develop more accurate predictive models based on these factors to predict extubation outcomes in neonatal.
More Related Videos
05:50International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
03:58Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...