Related Experiment Video
Updated: Sep 15, 2025

Optimization of Processing of Tiebangchui with Highland Barley Wine Based on the Box-Behnken Design Combined with the Entropy Method
Published on: May 19, 2023
Optimizing blended cement concrete strength using the Box-Behnken design technique
Solomon Oyebisi1,2, Mahaad Issa Shammas3, Mohammed Seyam4
1Civil Engineering and Geomatics Department, Durban University of Technology, Durban, South Africa. solomonO@dut.ac.za.
Abstract:
A properly optimized concrete mix design yields the required workability and strength for the fresh and hardened concrete to sustain desired loads and stresses over time, preventing premature failure. Thus, it is imperative to investigate the behavioural sensitivity of blended cement concrete to mix design variations. The research uses the Box-Behnken design of the response surface method to optimize the slump and compressive strength of blended cement concrete incorporating Shea nutshell ash (SNA). SNA was partially utilized as a Portland limestone cement (PLC) substitute at 5-15 wt% replacement levels using C25, C30, and C40 MPa mix design proportions and tested for compressive strength after 7-90 curing ages. Binder (SNA-to-PLC) ratio, water-to-binder ratio, binder-to-aggregate ratio, and curing age were engaged as continuous (independent) variables to optimize the response (dependent) variables (slump and compressive strength). The slump and compressive strength responses were optimized by the Box-Behnken design. The results exhibited a minimized slump and a maximized compressive strength with approximately 40-63% reduction and 10% increment. The correlations between the optimized and experimental variables were accurate and strong, with 98.89% and 98.44% R2 for slump and compressive strength. Ultimately, this response model is beneficial in determining the optimum mix design proportions to achieve the desired compressive strength of blended cement concrete incorporating repurposed waste materials.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Design Example: Managing Concrete Workability
Bonding and Strength of Aggregate
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Fatigue Strength of Concrete
Types of Cement II

