Related Experiment Video
Updated: Sep 15, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Design and Validation of a Wearable System for Enhanced Monitoring of Lower Limb Lymphedema
Sara Bernasconi1, Giovanni Maria Oriolo1, Giovanni Farina2
1Dipartimento di ElettronicaInformazione e Bioingegneria, Politecnico di Milano 20133 Milan Italy.
Abstract:
Lymphedema, characterized by limb swelling, is typically treated with Complex Decongestive Therapy (CDT), which includes physical exercise. This study seeks to design and validate a wearable device aimed at enhancing CDT by monitoring patient adherence to prescribed exercises and tracking changes in the range of motion of the affected limbs. A wearable device, constituted by two boards with 2 IMUs, connected by a flexible flat cable, was designed and developed for placement across targeted joints. It communicates wirelessly with PCs, where raw data from IMUs are collected. Through the application of the Madgwick filter, orientation of the units is obtained and finally joints angles are computed. The device was validated through bench testing using an orthopedic goniometer and field testing with an optoelectronic system. The in vivo validation involved 18 volunteers, including 10 healthy individuals and 8 individuals with lymphedema, who performed flexion-extension movements and walked on a treadmill (at speeds of 3 km/h and 5 km/h). Bench testing demonstrated strong correlation and agreement (r2=0.999, mean percentage error = -0.51°, standard deviation = 2.00°). Once worn by the participants, the device enabled the measurement of joint angles during flexion-extension exercises (r2=0.852, mean percentage error = 1.44°, standard deviation = 11.7°) and the extraction of step counting, step time and toe off during walk at different speeds. The developed wearable device exhibited robust performance in both bench and field testing. This device, designed specifically for lymphedema patients, offers valuable insights into limb function and exercise adherence, potentially improving personalized treatment strategies.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Artery Disease V: Postoperative Nursing Management
Development of the Lymphatic System
The first lymph sacs to form are the paired jugular lymph sacs located at the junction of the internal jugular and subclavian veins. From these sacs, lymphatic capillary plexuses extend to the thorax, upper limbs, neck, and head, eventually forming lymphatic vessels. Each jugular lymph sac maintains a...
Peripheral Artery Disease IV: Nursing Management
Assessing Blood pressure in the Leg
Preparation:

