Related Experiment Video
Updated: Sep 8, 2025
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)
Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment
Published on: April 25, 2025
Clinical evaluation of the novel FAP-targeting PET tracer 68 Ga-XT117 in solid tumors, its synergistic role, and
Zhihui Shen1, Qingxiao Li2, Jinglan Zhou3
1Department of Nuclear Medicine, Guang'anmen Hospital, China Academy of Chinese Medical Sciences.
Objective:
This study aimed to evaluate the diagnostic performance of the novel fibroblast activation protein-targeting PET tracer 68 Ga-XT117 compared with 18 F-fluorodeoxyglucose ( 18 F-FDG) in solid tumors.
Methods:
This single-center, prospective, open-label study enrolled 14 patients with solid tumors. Participants received 68 Ga-XT117 at different doses (3, 5, or 7 mCi) and underwent PET/CT scans at multiple time points. Image quality was assessed using maximum standardized uptake value and tumor-to-background ratio. All patients underwent both 68 Ga-XT117 and 18 F-FDG PET/CT within 1 week for head-to-head comparison.
Results:
68 Ga-XT117 demonstrated optimal imaging quality at a dose of 5 mCi with an acquisition time of 40-min postinjection. In the head-to-head comparison, 68 Ga-XT117 detected 137 lesions and 18F-FDG detected 138 lesions overall. 68 Ga-XT117 showed improved detection of primary lesions (23 vs. 20) and lymph node metastases (13 vs. 6) compared to 18 F-FDG. The tracer exhibited significantly higher uptake in sarcomas compared to gastrointestinal tumors ( P = 0.014). Additionally, 68 Ga-XT117 showed advantages in detecting certain lesion subtypes, particularly lymph node metastases, and bone lesions. The administration of 68 Ga-XT117 was well tolerated, and no adverse events were observed or reported during the study.
Conclusion:
68 Ga-XT117 demonstrates favorable diagnostic performance, particularly in low-metabolic tumors, with good safety and optimal imaging characteristics. The tracer shows a complementary value to 18 F-FDG in lesion detection. Further prospective studies are warranted to validate the clinical significance of the additionally detected lesions.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)
