Related Experiment Video
Updated: May 2, 2026

A Protocol of Manual Tests to Measure Sensation and Pain in Humans
Published on: December 19, 2016
Proprioceptive test for the temporomandibular joint: An intra- and inter-rater reliability study with healthy adults
Tzvika Greenbaum1, Noa Ravhon1, Danny Barshai1
1Department of Physical Therapy, Faculty of Health Sciences, Recanati School for Community Health Professions, Ben-Gurion University of the Negev, Be'er-Sheva, Israel.
Background:
Temporomandibular disorders (TMDs) are challenging to manage due to their multifactorial nature. As with other joints, the function of temporomandibular joint (TMJ) is influenced by proprioception, making it an essential factor in TMD management. However, previous studies on the joint position error (JPE) in TMD patients lacked a proper diagnosis and reliability assessment.
Objectives:
The aim of the present study was to develop a reliable JPE test in healthy adults as a foundation for future evaluation in TMD patients.
Material And Methods:
Two examiners conducted the JPE assessment, utilizing a methodology encompassing between-days intra-rater and within-day inter-rater reliability assessments. A total of 22 healthy participants (7 men and 15 women) with a mean unassisted mouth opening of 46 ±5 mm were recruited. The evaluation targeted specific distances (10 mm, 20 mm and 30 mm) within the participants' mouth opening range, with proprioceptive accuracy evaluated through the measurement of the absolute error (AE) and the constant error (CE).
Results:
The CE was consistently lower than AE across all the targeted distances, although with higher standard deviations. Intra-rater reliability varied across the distances, with poor reliability observed for AE at 10 mm, moderate reliability for CE at 10 mm, good reliability for both AE and CE at 20 mm, and moderate reliability for both AE and CE at 30 mm. Inter-rater reliability was moderate at 10 mm and good at 20 mm for both AE and CE, with equally moderate reliability levels at 30 mm.
Conclusions:
The 20 mm target distance demonstrated good intraand inter-rater reliability, warranting its evaluation in patients with TMDs in the subsequent investigation phase.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
06:37Temporomandibular Joint Pain Measurement by Bite Force and Von Frey Filament Assays in Mice
Published on: September 13, 2024
Related Concept Videos
Longitudinal Research
Assessment of the Gastrointestinal System II: Health Perception Pattern
Health Perception Patterns
Health perception patterns offer valuable insights into a patient's lifestyle habits and how they may impact their GI health. These patterns include:
Bioavailability Study Design: Healthy Subjects Versus Patients
Longitudinal Studies
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Relationship with Other Adult Family Members and Siblings