Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
Published on: June 21, 2024
Dual-Center Repeatability, Consistency, and Comparison of 3D Phase-Resolved Functional (PREFUL) Ventilation MRI at 3
Filip Klimeš1,2, Chuan T Foo3,4, Marcel Gutberlet1,2
1Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.
Abstract:
3D phase-resolved functional lung (PREFUL) MRI offers lung ventilation assessment without contrast and in free breathing. However, there are limited data on its repeatability and intercenter consistency. This study aimed to assess the repeatability and intercenter consistency of 3D PREFUL MRI at two centers using both 3- and 1.5-T field strengths. Fifty healthy volunteers (35 female, 70%; median age 25.5 [interquartile range 22.3-29.0 years]) participated in this prospective study. A golden-angle stack-of-stars spoiled gradient echo acquisition was used for 3D PREFUL MRI. To assess for repeatability, 3D PREFUL MRI was performed twice with a short interval between scans at each center. At Center 1, scans were performed at 3 and 1.5 T. At Center 2, scans were performed at 3 T. Intercenter consistency of 3D PREFUL MRI was assessed between centers at 3 T. Performance of 3D PREFUL MRI at 3 and 1.5 T was compared at Center 1. Bland-Altman analysis, coefficient of variation, intraclass correlation coefficient, and Cohen's d were used for the repeatability assessment. Similarly, interfield strength and intercenter differences were quantified by Bland-Altman analysis. In all comparisons, paired Wilcoxon signed-rank test was used to examine differences. 3D PREFUL MRI parameters showed no significant differences between repeated measurements across three scanners, except for mean regional ventilation (RVent) at Center 2 (p = 0.0046). Apart from mean RVent during the second measurement (p = 0.03) and tidal volume during both measurements (both p < 0.02), no significant differences were found between 3D PREFUL MRI parameters at 3 T across both centers. Output parameters were significantly different when images were acquired using 3 T compared to 1.5 T (all p < 0.0093). 3D PREFUL MRI ventilation-weighted parameters showed fair to excellent repeatability and consistent intercenter results. Given the significant differences in outputs acquired using scanners of different field strengths, multicenter studies should be conducted with scanners of the same field strength.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System IV: CMRI